Diagnosis
What this means
Sensor Viewer is available on supported ACU6 and ACU7 systems. A red or blocked state is not automatically a fault because some sensors are normally blocked or indicate conditions such as low cash.
Common causes
What may be happening
- A note may be blocking a dispenser sensor
- The receipt printer reports a blocked path
- The card reader shows a card when empty
- A sensor state does not change after the obstruction is removed
Operator-safe procedure
What to check first
- 01Open Diagnostics and select Sensor Viewer if it is available.
- 02Choose the affected device section: CDU, receipt printer, or card reader.
- 03Record the exact sensor names, colors, and states before touching anything.
- 04For a clearly visible, operator-accessible obstruction, remove loose material without moving the sensor; clean only exposed optical surfaces with an approved microfiber method.
- 05Refresh the view and confirm whether the state changed, then send the before-and-after sensor names to support if the fault remains.
Safety boundary
Stop and contact support if
- The obstruction is inside a secured or disassembly-required area
- The procedure would require moving or recalibrating a sensor
- The sensor remains blocked after the visible path is clear
- Cash, a card, or torn material cannot be safely removed