top of page

How to use the Genmega sensor viewer

Read Genmega CDU, printer, and card-reader sensor states and capture the exact evidence support needs.

GenmegaGenmega ATM systems running application software V05.00.40 or later

Diagnosis

What this means

Sensor Viewer is available on supported ACU6 and ACU7 systems. A red or blocked state is not automatically a fault because some sensors are normally blocked or indicate conditions such as low cash.

Common causes

What may be happening

  • A note may be blocking a dispenser sensor
  • The receipt printer reports a blocked path
  • The card reader shows a card when empty
  • A sensor state does not change after the obstruction is removed

Operator-safe procedure

What to check first

  1. 01Open Diagnostics and select Sensor Viewer if it is available.
  2. 02Choose the affected device section: CDU, receipt printer, or card reader.
  3. 03Record the exact sensor names, colors, and states before touching anything.
  4. 04For a clearly visible, operator-accessible obstruction, remove loose material without moving the sensor; clean only exposed optical surfaces with an approved microfiber method.
  5. 05Refresh the view and confirm whether the state changed, then send the before-and-after sensor names to support if the fault remains.

Safety boundary

Stop and contact support if

  • The obstruction is inside a secured or disassembly-required area
  • The procedure would require moving or recalibrating a sensor
  • The sensor remains blocked after the visible path is clear
  • Cash, a card, or torn material cannot be safely removed