Diagnosis
What this means
Genmega error C007X means Sensor failure. One or multiple dispenser sensors are blocked or defective.
Common causes
What may be happening
- The Sensor failure condition may be caused by a note, dust, or a sensor that remains active or out of position.
Operator-safe procedure
What to check first
- 01Check for jammed notes or other obstructions to the dispenser sensors. Reboot the ATM.
- 02Clean the dispenser sensors as needed. Check the sensor cables.
- 03Check the CDU Setup screen in the Operator Functions, and make sure the mini-CD type setting is correct.
- 04Qualified-service step: if this error persists, replace the dispenser or send it in for repair.
- 05Run the dispenser diagnostic, reconcile any moved or rejected notes, and confirm the dispenser returns ready without the code.
Safety boundary
Stop and contact support if
- The remaining remedy requires qualified service: if this error persists, replace the dispenser or send it in for repair.
- Stop if the obstruction is behind a guard, will not release with light hand pressure, or requires disassembling the mechanism.
- Stop if the named sensor remains blocked after visible debris is removed; do not bend, relocate, or electrically probe the sensor.
- Do not move calibrated sensors, probe powered circuits, or disconnect internal boards unless you are trained and authorized for that ATM model.