top of page

Genmega C00FF: Sensor blocked

Genmega error C00FF indicates Sensor blocked. Start with: Check for jammed notes in the cash dispenser. If no bills are present, try using compressed air to clean the dispenser (a sensor may be blocked by dust).

GenmegaGenmega ATM familyError C00FF

Diagnosis

What this means

Genmega error C00FF means Sensor blocked. An undefined dispenser sensor is blocked.

Common causes

What may be happening

  • The Sensor blocked condition may be caused by a note, dust, or a sensor that remains active or out of position.

Operator-safe procedure

What to check first

  1. 01Check for jammed notes in the cash dispenser. If no bills are present, try using compressed air to clean the dispenser (a sensor may be blocked by dust).
  2. 02If this is a Hyosung-brand ATM.
  3. 03Check the CDU sensor diagnostic screen to identify and locate the blocked sensor. Wipe the sensor off with a damp rag and check its wiring.
  4. 04Qualified-service step: if this error persists, replace the dispenser or send it in for repair.

Safety boundary

Stop and contact support if

  • The remaining remedy requires qualified service: if this error persists, replace the dispenser or send it in for repair.
  • Stop if the obstruction is behind a guard, will not release with light hand pressure, or requires disassembling the mechanism.
  • Stop if the named sensor remains blocked after visible debris is removed; do not bend, relocate, or electrically probe the sensor.