Diagnosis
What this means
Genmega error C00C7 means CS12 Sensor blocked.
Common causes
What may be happening
- The CS12 Sensor blocked condition may be caused by a note, dust, or a sensor that remains active or out of position.
Operator-safe procedure
What to check first
- 01MB2100T - The CS12 sensor, which is located at the upper part of the cash tray was blocked while the machine was either dispensing or initializing.
- 02Clear the cash tray of any bills or foreign objects.
- 03If the error persists, the vault assembly may need to be removed to inspect.
- 04Access the cash tray sensors.
- 05Repeat the operation that triggered error C00C7 and confirm the same code does not return.
Safety boundary
Stop and contact support if
- Stop if the obstruction is behind a guard, will not release with light hand pressure, or requires disassembling the mechanism.
- Stop if the named sensor remains blocked after visible debris is removed; do not bend, relocate, or electrically probe the sensor.
- Do not move calibrated sensors, probe powered circuits, or disconnect internal boards unless you are trained and authorized for that ATM model.
- Take the affected function out of service and contact PayTree support if error C00C7 returns after the listed correction and retest.