Diagnosis
What this means
Genmega error C00C9 means CS12 & CS14 Sensors blocked.
Common causes
What may be happening
- The CS12 & CS14 Sensors blocked condition may be caused by a note, dust, or a sensor that remains active or out of position.
Operator-safe procedure
What to check first
- 01MB2100T - Both the CS12 and CS14 sensors were blocked while the machine was either dispensing or initializing.
- 02These sensors are located in the cash tray and prevent tampering with the bill path.
- 03Clear the cash tray of any bills or foreign objects.
- 04If the error persists, the vault assembly may need to be removed to inspect.
- 05Access the cash tray sensors.
- 06Repeat the operation that triggered error C00C9 and confirm the same code does not return.
Safety boundary
Stop and contact support if
- Stop if the obstruction is behind a guard, will not release with light hand pressure, or requires disassembling the mechanism.
- Stop if the named sensor remains blocked after visible debris is removed; do not bend, relocate, or electrically probe the sensor.
- Do not move calibrated sensors, probe powered circuits, or disconnect internal boards unless you are trained and authorized for that ATM model.
- Take the affected function out of service and contact PayTree support if error C00C9 returns after the listed correction and retest.
Keep learning