top of page

How to use the Genmega error summary

Find repeated Genmega errors, including communication failures that may not leave a code on the customer screen.

GenmegaGenmega ATM systems running application software V05.00.40 or later

Diagnosis

What this means

The Error Summary groups recorded codes and shows how often each occurred. Common status codes can appear alongside faults, so frequency and timing matter.

Common causes

What may be happening

  • The ATM went out of service without a visible code
  • One recurring fault is hidden among older entries
  • A communication problem cleared before inspection

Operator-safe procedure

What to check first

  1. 01Open Reports and select Error Summary.
  2. 02Record or print the current list before clearing anything.
  3. 03Identify the highest-frequency codes and the codes associated with the latest outage.
  4. 04If authorized to isolate a new failure, clear the summary only after preserving the existing evidence, then perform one normal transaction or device test.
  5. 05Reopen Error Summary and use the newly recorded code to choose the specific troubleshooting article.

Safety boundary

Stop and contact support if

  • The menu, labels, or available options do not match the article or your software version
  • The next step would expose credentials, encryption keys, host addresses, or restricted processor settings
  • The ATM reports tampering, physical damage, an electrical problem, or a trapped card or cash beyond ordinary operator access
  • The issue returns after one approved check and one normal retest

Keep learning