Diagnosis
What this means
Genmega error C0086 means Note not arriving at count sensor #0 or #1 after leaving reject gate timing sensor #2 or #3. A bill did not arrive at the count sensor after leaving the reject gate timing sensor.
Common causes
What may be happening
- A note, paper fragment, or foreign object may be obstructing the specific path or sensor named in the error (Note not arriving at count sensor #0 or #1).
- Dust or residue may be preventing Inspect the count sensor and reject timing sensors and clean as needed. Inspect the sensor cabling from changing state correctly.
- The Note not arriving at count sensor #0 or #1 component or its control electronics may have failed.
Operator-safe procedure
What to check first
- 01Inspect the CDU for bill jams. Remove any jams found.
- 02Inspect the count sensor and reject timing sensors and clean as needed. Inspect the sensor cabling.
- 03Qualified-service step: if the error persists, replace the dispenser or send it in for repair.
- 04Check Note path and sensor.
- 05Run the dispenser diagnostic, reconcile any moved or rejected notes, and confirm the dispenser returns ready without the code.
Safety boundary
Stop and contact support if
- The remaining remedy requires qualified service: if the error persists, replace the dispenser or send it in for repair.
- Stop if the named sensor remains blocked after visible debris is removed; do not bend, relocate, or electrically probe the sensor.
- Do not move calibrated sensors, probe powered circuits, or disconnect internal boards unless you are trained and authorized for that ATM model.
- Take the affected function out of service and contact PayTree support if error C0086 returns after the listed correction and retest.