top of page

Genmega C0013: Both reject gate and exit sensor not cleared

Genmega error C0013 indicates Both reject gate and exit sensor not cleared. Start with: Check dispenser for any notes or obstructions.

GenmegaGenmega ATM familyError C0013

Diagnosis

What this means

Genmega error C0013 means Both reject gate and exit sensor not cleared.

Common causes

What may be happening

  • The Both reject gate and exit sensor not cleared condition may be caused by a note, dust, or a sensor that remains active or out of position.

Operator-safe procedure

What to check first

  1. 01Check dispenser for any notes or obstructions.
  2. 02Run the dispenser diagnostic, reconcile any moved or rejected notes, and confirm the dispenser returns ready without the code.

Safety boundary

Stop and contact support if

  • Stop if the named sensor remains blocked after visible debris is removed; do not bend, relocate, or electrically probe the sensor.
  • Do not move calibrated sensors, probe powered circuits, or disconnect internal boards unless you are trained and authorized for that ATM model.
  • Take the affected function out of service and contact PayTree support if error C0013 returns after the listed correction and retest.