Genmega C001x: CDU sensor is tripped

Genmega error C001X indicates CDU sensor is tripped. Start with: Check the front of the CDU and the cash tray for blockage. Clear any blockages found.

GenmegaGenmega ATM familyError C001X

Diagnosis

What this means

Genmega error C001X means CDU sensor is tripped. This error indicates that during a dispense, the sensor located at the front of the CDU shows a blockage (usually the Exit, CS13 or CS2 sensors - refer to CDU sensor diagnostics screen if this is a Hyosung ATM in order to identify affected sensors). This is usually caused by a bill bouncing back from the cash tray (sometimes due to a customer's fingers reaching too far into the cash tray).

Common causes

What may be happening

  • This error indicates that during a dispense, the sensor located at the front of the CDU shows a blockage (usually the Exit, CS13 or CS2 sensors - refer to CDU sensor diagnostics screen if this is a Hyosung ATM in order to identify affected sensors).
  • This is usually caused by a bill bouncing back from the cash tray (sometimes due to a customer's fingers reaching too far into the cash tray).
  • Dust or residue may be preventing the Exit, CS2, and CS13, or any other sensors found near the front of the dispenser as needed from changing state correctly.
  • A cable or connector associated with CDU sensor is tripped may be loose, disconnected, or damaged.

Operator-safe procedure

What to check first

  1. 01Check the front of the CDU and the cash tray for blockage. Clear any blockages found.
  2. 02Clean the Exit, CS2, and CS13, or any other sensors found near the front of the dispenser as needed.
  3. 03Qualified-service step: have a qualified technician inspect sensor cables. Reseat the sensor cable on the dispenser control board.
  4. 04Qualified-service step: reinitialize the ATM to put back in service. If the error persists, replace the dispenser or send it in for repair.
  5. 05Run the dispenser diagnostic, reconcile any moved or rejected notes, and confirm the dispenser returns ready without the code.

Safety boundary

Stop and contact support if

  • The remaining remedy requires qualified service: have a qualified technician inspect sensor cables. Reseat the sensor cable on the dispenser control board; reinitialize the ATM to put back in service. If the error persists, replace the dispenser or send it in for repair.
  • Stop if the named sensor remains blocked after visible debris is removed; do not bend, relocate, or electrically probe the sensor.
  • Do not move calibrated sensors, probe powered circuits, or disconnect internal boards unless you are trained and authorized for that ATM model.
  • Take the affected function out of service and contact PayTree support if error C001X returns after the listed correction and retest.