Diagnosis
What this means
Genmega error C001X means CDU sensor is tripped. This error indicates that during a dispense, the sensor located at the front of the CDU shows a blockage (usually the Exit, CS13 or CS2 sensors - refer to CDU sensor diagnostics screen if this is a Hyosung ATM in order to identify affected sensors). This is usually caused by a bill bouncing back from the cash tray (sometimes due to a customer's fingers reaching too far into the cash tray).
Common causes
What may be happening
- This error indicates that during a dispense, the sensor located at the front of the CDU shows a blockage (usually the Exit, CS13 or CS2 sensors - refer to CDU sensor diagnostics screen if this is a Hyosung ATM in order to identify affected sensors).
- This is usually caused by a bill bouncing back from the cash tray (sometimes due to a customer's fingers reaching too far into the cash tray).
- Dust or residue may be preventing the Exit, CS2, and CS13, or any other sensors found near the front of the dispenser as needed from changing state correctly.
- A cable or connector associated with CDU sensor is tripped may be loose, disconnected, or damaged.
Operator-safe procedure
What to check first
- 01Check the front of the CDU and the cash tray for blockage. Clear any blockages found.
- 02Clean the Exit, CS2, and CS13, or any other sensors found near the front of the dispenser as needed.
- 03Qualified-service step: have a qualified technician inspect sensor cables. Reseat the sensor cable on the dispenser control board.
- 04Qualified-service step: reinitialize the ATM to put back in service. If the error persists, replace the dispenser or send it in for repair.
- 05Run the dispenser diagnostic, reconcile any moved or rejected notes, and confirm the dispenser returns ready without the code.
Safety boundary
Stop and contact support if
- The remaining remedy requires qualified service: have a qualified technician inspect sensor cables. Reseat the sensor cable on the dispenser control board; reinitialize the ATM to put back in service. If the error persists, replace the dispenser or send it in for repair.
- Stop if the named sensor remains blocked after visible debris is removed; do not bend, relocate, or electrically probe the sensor.
- Do not move calibrated sensors, probe powered circuits, or disconnect internal boards unless you are trained and authorized for that ATM model.
- Take the affected function out of service and contact PayTree support if error C001X returns after the listed correction and retest.