Diagnosis
What this means
Genmega error C0011 means Exit sensor is not cleared.
Common causes
What may be happening
- The Exit sensor is not cleared condition may be caused by a note, dust, or a sensor that remains active or out of position.
Operator-safe procedure
What to check first
- 01Check sensor.
- 02Verify that the cabling plugged into the sensor boards is secure.
- 03Repeat the operation that triggered error C0011 and confirm the same code does not return.
Safety boundary
Stop and contact support if
- Stop if the named sensor remains blocked after visible debris is removed; do not bend, relocate, or electrically probe the sensor.
- Do not move calibrated sensors, probe powered circuits, or disconnect internal boards unless you are trained and authorized for that ATM model.
- Take the affected function out of service and contact PayTree support if error C0011 returns after the listed correction and retest.