Diagnosis
What this means
Tranax error F0006 means Dispense limit set error (must be less than 25 notes).
Common causes
What may be happening
- The ATM programming may not match the processor-approved or device-approved settings.
Operator-safe procedure
What to check first
- 01Set Dispense limit - (Transaction Setup).
- 02Run the dispenser diagnostic, reconcile any moved or rejected notes, and confirm the dispenser returns ready without the code.
Safety boundary
Stop and contact support if
- Take the affected function out of service and contact PayTree support if error F0006 returns after the listed correction and retest.