Diagnosis
What this means
Tranax error D170X means Modem cannot support connection - excessive line noise (usualy D1704/06).
Common causes
What may be happening
- The ATM programming may not match the processor-approved or device-approved settings.
Operator-safe procedure
What to check first
- 01Phone line connected to ATM will not support Data-communication.
- 02In line filter may fix this.
- 03Excessive EMI emissions from outside source (neon sign, freezer).
- 04Run one communication test and confirm that the ATM reaches the host and returns to its normal ready state.
Safety boundary
Stop and contact support if
- Stop before changing processor host values or internal communication boards; preserve the approved settings and escalate with the communication-test result.
- Take the affected function out of service and contact PayTree support if error D170X returns after the listed correction and retest.
Keep learning