Tranax C0055: Detected long notes at outlet sensor

Tranax error C0055 indicates Detected long notes at outlet sensor. Start with: Check quality of cash.

TranaxTranax multi-model/general mainboard referenceError C0055

Diagnosis

What this means

Tranax error C0055 means Detected long notes at outlet sensor.

Common causes

What may be happening

  • The ATM detected the specific condition described as “Detected long notes at outlet sensor”.
  • The named Detected long notes at outlet sensor may be blocked, out of position, dirty, or not changing state.

Operator-safe procedure

What to check first

  1. 01Check quality of cash.
  2. 02Verify that denomination matches actual loaded cash.
  3. 03Run the dispenser diagnostic, reconcile any moved or rejected notes, and confirm the dispenser returns ready without the code.

Safety boundary

Stop and contact support if

  • Stop if the named sensor remains blocked after visible debris is removed; do not bend, relocate, or electrically probe the sensor.
  • Do not move calibrated sensors, probe powered circuits, or disconnect internal boards unless you are trained and authorized for that ATM model.
  • Take the affected function out of service and contact PayTree support if error C0055 returns after the listed correction and retest.