Diagnosis
What this means
Part 45323611 is the small S3M219-type CDU drive belt with specification B80S3M219:11. It is not interchangeable with the medium or large dispenser belts. A generic dispense failure does not prove this belt has failed, and the internal belt must be inspected or replaced only by qualified service.
Common causes
What may be happening
- The test note is worn, folded, or unsuitable for dispensing.
- The cassette is not seated normally or its note stack is loaded inconsistently.
- The small drive belt or another drive component is not transmitting movement normally.
- A clutch, sensor, motor, or control fault is producing a similar repeatable stop.
Operator-safe procedure
What to check first
- 01Take the ATM out of customer service and record the exact error, cassette, denomination, and whether a note or dispenser mechanism begins to move.
- 02Using the normal authorized cash-loading procedure, confirm that the cassette is seated normally and that its notes are flat, aligned, and not overpacked.
- 03Use one approved ATM test note and run one authorized dispenser diagnostic, recording whether movement starts, stops immediately, or stops at a consistent stage.
- 04Do not repeat the test after the same failure; record any clicking, slipping, grinding, or irregular cycling without opening the dispenser.
- 05Send PayTree support the ATM model, installed dispenser identification, test result, sound description, and belt references 45323611 and B80S3M219:11 before ordering.
Safety boundary
Stop and contact support if
- Stop if the cassette will not seat normally, notes are inaccessible, or any movement requires force.
- Stop after one failed controlled test or immediately if the dispenser clicks, grinds, slips repeatedly, or cycles without completing.
- Do not inspect, tension, remove, or replace the belt or service internal drive components, sensors, motors, boards, or wiring; arrange qualified repair service.