top of page

How to schedule a Genmega total report

Schedule a Trial Day Total or Day Total at the processor cutoff and understand whether the host totals reset.

GenmegaGenmega ATM systems running application software V05.00.40 or later

Diagnosis

What this means

Scheduled Total writes the selected total to the electronic journal. Trial Day Total does not reset host totals; Day Total does.

Common causes

What may be happening

  • The scheduled time does not match the processor cutoff
  • Day Total was selected when a non-resetting report was intended
  • The journal is not being reviewed or retained

Operator-safe procedure

What to check first

  1. 01Obtain the correct daily cutoff time from the processor or dealer.
  2. 02Open Scheduled Total and choose Trial Day Total for a non-resetting comparison or Day Total only when resetting the host period is intended.
  3. 03Set the schedule time to the confirmed cutoff.
  4. 04Verify the next journal entry appears at the expected time.
  5. 05Reconcile the recorded total with processor reporting and correct the schedule if the periods do not align.

Safety boundary

Stop and contact support if

  • You are not authorized to reset host totals
  • The processor cutoff time is unknown
  • A total is missing from the journal
  • The scheduled report creates a reconciliation difference

Keep learning

Related PayTree guides

How to schedule a Genmega total report

How to schedule a Genmega total report

bottom of page