Diagnosis
What this means
Reject Analysis records transactions in which the dispenser diverted one or more notes to the reject bin.
Common causes
What may be happening
- Notes are folded, worn, damp, or sticking together
- The cassette is loaded incorrectly
- A feed, thickness, or transport sensor is dirty or misreading
- A mechanical dispenser fault is developing
Operator-safe procedure
What to check first
- 01Open Reports and select Reject Analysis.
- 02Record the affected cassette, count, and pattern of rejected notes.
- 03Inspect the reject bin and the removed notes; replace visibly damaged or unsuitable currency.
- 04Fan and reload a properly prepared stack in the correct cassette orientation, then run one approved dispenser test.
- 05If rejects remain excessive, preserve the report and contact support for model-specific cleaning or service rather than repeatedly testing cash.
Safety boundary
Stop and contact support if
- The reject bin contains torn currency or evidence of a jam inside the transport
- A sensor or feed assembly requires disassembly
- Repeated tests continue diverting good notes
- The cash count cannot be reconciled
Keep learning