top of page

Genmega CDN12: No Response (ENQ-ACK) after 5 retry of ENQ

Genmega error CDN12 indicates No Response between ENQ-ACK after 5 retry of ENQ. Start with: Reboot the ATM.

GenmegaGenmega ATM familyError CDN12

Diagnosis

What this means

Genmega error CDN12 means No Response between ENQ-ACK after 5 retry of ENQ. The CDU did not respond to a command from the main board.

Common causes

What may be happening

  • A cable or connector associated with No Response between ENQ-ACK may be loose, disconnected, or damaged.
  • The ATM programming may not match the processor-approved or device-approved settings.

Operator-safe procedure

What to check first

  1. 01Reboot the ATM.
  2. 02Check the CDU communication and power cables. Reseat the cable connections as needed.
  3. 03Check dispenser settings in CDU Setup. If any setting need to be corrected, be sure to press "Execute" before exiting the CDU Setup screen.
  4. 04Qualified-service step: have a qualified technician inspect the dispenser control board dipswitch settings.
  5. 05Qualified-service step: clear NVRAM and check the dispenser settings in CDU Setup again.
  6. 06Qualified-service step: if this error persists, it may be caused by a failure of the CDU control board, the CDU communication cable, or the main board. Replace the parts or send them in for repair.
  7. 07Qualified-service step: have a qualified technician inspect connection between Main board and CDU.
  8. 08Run one communication test and confirm that the ATM reaches the host and returns to its normal ready state.

Safety boundary

Stop and contact support if

  • The remaining remedy requires qualified service: have a qualified technician inspect the dispenser control board dipswitch settings; clear NVRAM and check the dispenser settings in CDU Setup again.
  • Stop before changing processor host values or internal communication boards; preserve the approved settings and escalate with the communication-test result.
  • Do not move calibrated sensors, probe powered circuits, or disconnect internal boards unless you are trained and authorized for that ATM model.
  • Take the affected function out of service and contact PayTree support if error CDN12 returns after the listed correction and retest.