Diagnosis
What this means
Genmega error C0082 means Note leaving cassette exit sensor did not reach DD.
Common causes
What may be happening
- A note, paper fragment, or foreign object may be obstructing the specific path or sensor named in the error (Note leaving cassette exit sensor did not reach DD).
Operator-safe procedure
What to check first
- 01A note seen at cassette exit sensors did not reach the double detect module.
- 02Check for jammed notes.
- 03Run the dispenser diagnostic, reconcile any moved or rejected notes, and confirm the dispenser returns ready without the code.
Safety boundary
Stop and contact support if
- Stop if the obstruction is behind a guard, will not release with light hand pressure, or requires disassembling the mechanism.
- Stop if the named sensor remains blocked after visible debris is removed; do not bend, relocate, or electrically probe the sensor.
- Do not move calibrated sensors, probe powered circuits, or disconnect internal boards unless you are trained and authorized for that ATM model.
- Take the affected function out of service and contact PayTree support if error C0082 returns after the listed correction and retest.
Keep learning