Genmega C0082: Note leaving cassette exit sensor did not reach DD

Genmega error C0082 indicates Note leaving cassette exit sensor did not reach DD. Start with: A note seen at cassette exit sensors did not reach the double detect module.

GenmegaGenmega ATM familyError C0082

Diagnosis

What this means

Genmega error C0082 means Note leaving cassette exit sensor did not reach DD.

Common causes

What may be happening

  • A note, paper fragment, or foreign object may be obstructing the specific path or sensor named in the error (Note leaving cassette exit sensor did not reach DD).

Operator-safe procedure

What to check first

  1. 01A note seen at cassette exit sensors did not reach the double detect module.
  2. 02Check for jammed notes.
  3. 03Run the dispenser diagnostic, reconcile any moved or rejected notes, and confirm the dispenser returns ready without the code.

Safety boundary

Stop and contact support if

  • Stop if the obstruction is behind a guard, will not release with light hand pressure, or requires disassembling the mechanism.
  • Stop if the named sensor remains blocked after visible debris is removed; do not bend, relocate, or electrically probe the sensor.
  • Do not move calibrated sensors, probe powered circuits, or disconnect internal boards unless you are trained and authorized for that ATM model.
  • Take the affected function out of service and contact PayTree support if error C0082 returns after the listed correction and retest.