top of page

Genmega C0062: 3rd cassette inlet sensor not cleared

Genmega error C0062 indicates 3rd cassette exit sensor not cleared (left or right) %u2013 Before dispense. Start with: Inspect the dispenser for bill jams. Remove any jams or other obstructions.

GenmegaGenmega ATM familyError C0062

Diagnosis

What this means

Genmega error C0062 means 3rd cassette exit sensor not cleared (left or right) %u2013 Before dispense. The exit sensor behind the 3rd cassette was not cleared before a dispense.

Common causes

What may be happening

  • The 3rd cassette exit sensor not cleared (left or right) %u2013 Before dispense condition may be caused by a note, dust, or a sensor that remains active or out of position.

Operator-safe procedure

What to check first

  1. 01Inspect the dispenser for bill jams. Remove any jams or other obstructions.
  2. 02Inspect the 3rd cassette exit sensors and clean as needed. Also check the sensor cable connections.
  3. 03If the sensors are being blocked by a bill that is not fully fed out of the 3rd cassette, the problem could be with the cassette. Replace the cassette if needed.
  4. 04Qualified-service step: if this error persists, replace the dispenser or send it in for repair.
  5. 05Run the dispenser diagnostic, reconcile any moved or rejected notes, and confirm the dispenser returns ready without the code.

Safety boundary

Stop and contact support if

  • The remaining remedy requires qualified service: if this error persists, replace the dispenser or send it in for repair.
  • Stop if the named sensor remains blocked after visible debris is removed; do not bend, relocate, or electrically probe the sensor.
  • Do not move calibrated sensors, probe powered circuits, or disconnect internal boards unless you are trained and authorized for that ATM model.
  • Take the affected function out of service and contact PayTree support if error C0062 returns after the listed correction and retest.

Keep learning

Related PayTree guides

Genmega C0062: 3rd cassette inlet sensor not cleared

Genmega C0062: 3rd cassette inlet sensor not cleared

bottom of page