Diagnosis
What this means
Genmega error 20012 means Receipt printer feed lever open. The printer detects that the feed lever has not been completely closed.
Common causes
What may be happening
- The Receipt printer feed lever open component or its control electronics may have failed.
Operator-safe procedure
What to check first
- 01Close the feed tray on the printer.
- 02If the paper tray is already closed, try opening and closing the tray.
- 03Qualified-service step: try performing a reset using the printer reset switch on the printer control board.
- 04Qualified-service step: if the error persists, repair or replace the printer assembly.
- 05Run the receipt-printer test and confirm that paper feeds, prints, and cuts normally without the code returning.
Safety boundary
Stop and contact support if
- The remaining remedy requires qualified service: try performing a reset using the printer reset switch on the printer control board; if the error persists, repair or replace the printer assembly.
- Stop if the obstruction is behind a guard, will not release with light hand pressure, or requires disassembling the mechanism.
- Stop if the paper cannot be cleared with paper or a plastic card, the drawer will not release normally, or printer removal is required.
- Do not move calibrated sensors, probe powered circuits, or disconnect internal boards unless you are trained and authorized for that ATM model.
Keep learning