Diagnosis
What this means
Genmega error 20003 means Reject Bin is Full. The ATM's reject count has hit its maximum.
Common causes
What may be happening
- The ATM's reject count has hit its maximum.
- The reject bin may contain the maximum allowed number of diverted notes.
- The ATM's stored reject count may still be at its maximum even when the physical reject bin is empty.
Operator-safe procedure
What to check first
- 01Remove all notes from the physical reject bin.
- 02From the Settlement menu, run Cassette Total to reset and reconcile the stored reject count, even if the reject bin was already empty.
- 03Qualified-service step: have a qualified technician inspect that AP, BIOS, and CDU ROM versions are compatible.
- 04Run the dispenser diagnostic, reconcile any moved or rejected notes, and confirm the dispenser returns ready without the code.
Safety boundary
Stop and contact support if
- The remaining remedy requires qualified service: have a qualified technician inspect that AP, BIOS, and CDU ROM versions are compatible.
- Take the affected function out of service and contact PayTree support if error 20003 returns after the listed correction and retest.
Keep learning